Sentry US ACSK-EM Manual de usuario Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 14
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
8
The Factory Default Programming/Admin Code is 1 2 3 4.
To enter Setup Mode press Programming Code twice.
(ex: 1 2 3 4 1 2 3 4) The mode LED indicator will turn yellow.
To exit or quit from the Setup Mode, press # key.
CHANGING PROGRAMMING/ADMIN CODE
1. In Setup Mode, press * key and 3. The mode indictor will flash yellow.
2. Enter new Programming Code twice (ex: 5 6 7 8 5 6 7 8). A long beep means
Programming Code was changed. The length of the Programming/Admin Code must
be the same as the old one.
3. Exit Setup Mode.
RESTORING THE PROGRAMMING/ADMIN CODE TO FACTORY DEFAULT
*Only if you cannot remember your new Programming Code.
1. Turn off control keypad power.
2. While pressing # key, turn on the power of the control keypad. A long beeps means
the default Programming Code was restored. (Programming/Admin Code is 1 2 3 4)
3. Exit Setup Mode.
ACCESS MODE SETTING
Card Access Only:
1. In Setup Mode, press * key and 0. The mode LED indicator will flash yellow.
2. Press 0 twice. The mode LED indicator will turn yellow and a long beep will sound.
Card & Code Access:
1. In Setup Mode, press * key and 0. The mode LED indicator will flash yellow.
2. Press 0 and 1. The mode LED indicator will turn yellow and a long beep will sound.
Combined Access:
1. In Setup Mode, press * key and 0. The mode LED indicator will flash yellow.
2. Press 0 and 2. The mode LED indicator will turn yellow and a long beep will sound.
To exit or quit from Setup Mode, press # key.
LENGTH OF PASSWORD SETTING
1. In Setup Mode, press * key and 9. The mode LED indicator will flash yellow.
2. Press 0 and 4. When a “BI” sound beeps, enter X (X = 2 / 3 / 4 / 5 / 6).
Note: 2 = length of 2 digits (00-99)
3 = length of 3 digits (000-999)
4 = length of 4 digits (0000-9999)
5 = length of 5 digits (00000-99999)
6 = length of 6 digits (000000-999999)
A “BI” sound means digit length setting is successful. A “BI BI BI” sounds means digit length is
the same as the existing, so setting is not permitted.
To exit or quit from Setup Mode, press # key.
IMPORTANT NOTE: In case the digit length changed, all added cards and passwords will be
cleared.